Operating Environment H045 En
Operating environment temperature and humidity:
+5°C +35°C (+41°F +95°F); less than 85%RH (cooling
vents not blocked)
Do not install in the following locations
Location exposed to direct sunlight or strong artificial
light
Location exposed to high humidity, or poorly ventilated
location
VENTILATION: When installing this unit, make sure
to leave space around the unit for ventilation to improve heat
radiation (at least 20 cm at top, 50 cm at rear, and 10 cm at
each side).
WARNING: Slot and openings in the cabinet are
provided for ventilation and to ensure reliable operation of the
product and to protect it from overheating, to prevent fire
hazard, the openings should never be blocked and covered
with items, such as newspapers, tablecloths, curtains, etc. Also
do not put the apparatus on the thick carpet, bed, sofa, or
fabric having a thick pile. H040 En
When using this product follow the instructions
written on the underside of the unit, which concern
rated voltage, etc.
This product is for general household purposes. Any
failure due to use for other than household purposes
(such as long-term use for business purposes in a
restaurant or use in a car or ship) and which requires
repair will be charged for even during the warranty
period.
K041_En
TWO VOLTAGE SELECTOR
SWITCHES (multi-voltage
model only)
Only multi-voltage model is provided with these
switches. Mains voltages in Saudi Arabia are 127 V
and 220 V only. Never use this model with the 110 V
setting in Saudi Arabia.
Only multi-voltage model is provided with
this(these) switch(switches).
U.S. and Canadian models are not pro-vided with these
switches. H014 En
The line voltage selector switches are on the rear panel.
Check that they are set properly before plugging the
power cord into the household wall socket. If the
voltage is not properly set or if you move to an area
where the voltage requirements differ, adjust the selector
switches as follows.
1. Use a medium-size screwdriver.
2. First, insert the screwdriver in the groove of the
voltage selector at the right, and adjust so that the tip
of the groove points to the voltage value of your area.
3. Next, insert the screwdriver in the groove of the
voltage selector at the left and adjust until the voltage
is the same as at the right.
CAUTION 220 V
Power source voltage is factory adjusted 220 volts. If your
area is different, change voltage selectors settings.
TWO VOLTAGE
SELECTORS
220V
110V 120 -127V
240V
220V
240V
110V
120-127V