Pink (CAR SPEED SIGNAL INPUT)
The mobile navigation system is connected here to detect the distance
the vehicle travels. Always connect the vehicle’s speed detection
circuit or the ND-PG1 speed pulse generator, sold separately. Failure
to make this connection will increase errors in the location display.
IMPROPER CONNECTION MAY RESULT IN SERIOUS
DAMAGE OR INJURY INCLUDING ELECTRICAL SHOCK,
AND INTERFERENCE WITH THE OPERATION OF THE
VEHICLE’S ANTILOCK BRAKING SYSTEM, AUTOMATIC
GEARBOX AND SPEEDOMETER INDICATION.
Light green
Used to detect the ON/OFF status of the handbrake. This lead must be
connected to the power supply side of the handbrake switch. If this
connection is made incorrectly or omitted, certain functions of
your navigation system will be unusable.
LIGHT GREEN LEAD AT POWER
CONNECTOR IS DESIGNED TO DETECT
PARKED STATUS AND MUST BE
CONNECTED TO THE POWER SUPPLY SIDE
OF THE HANDBRAKE SWITCH. IMPROPER
CONNECTION OR USE OF THIS LEAD MAY
VIOLATE APPLICABLE LAW AND MAY
RESULT IN SERIOUS INJURY OR DAMAGE.
11
Connecting the System
ENG/MASTER 96
12
Connecting the power cord (2)
Note: The position of the speed
detection circuit depends on the
vehicle model. For details, consult
your authorised Pioneer dealer or
an installation professional.
If connection to the speed detec-
tion circuit is too difficult, connect
the separately sold ND-PG1 speed
pulse generator to the pink lead.
Note: The position of the hand-
brake switch depends on the vehi-
cle model. For details, consult the
vehicle owner’s manual or dealer.
Connection method
Clamp the handbrake switch
power supply side lead.
Clamp firmly with
needle-nosed pliers.
Power supply side
Earth side
Handbrake switch
Hide-away unit
Speed detection circuit lead
Vehicle injection
computer
Connector
Pass the extension cord
and the lead for the speed
detection circuit through
this hole.
Clamp firmly with
needle-nosed
pliers.
Close the cover.
Connection method
Extension lead
(for speed signal)