Pioneer PDP-614MX External Control Manual RS-232C Manuel d'utilisateur Page 54

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 60
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 53
PDP-614MX External Control Manual
54
67. AUTO ID SET START
Function
External control apparatus sets up ID automatically to two or more plasma monitors.
Transmission Data
5FH 80H 60H F0H 01H DATA00 CKS
DATA00 00H~FFH: ID of a master
*1
is set up.
*: When you use it by the multi-system, please remove the link input of a master
*1
.
*1: “Master” means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution.
68. PLE LINK
Function
External control apparatus sets up equally PLE between two or more plasma monitors.
Transmission Data
DFH 80H 60H F1H 03H DATA00 to DATA02 CKS
DATA00 00H:PLE LINK ON
01H:PLE LINK OFF
DATA01 FFH(fixed)
DATA02 FFH(fixed)
*:Turn on the AUTO ID and set the DIVIDER(at 1,4 or 9), before this operation
69. VIDEO WALL SETTING
Function
External control apparatus sets 4screens or 9screens as a video wall.
Transmission Data
DFH 80H 60H F3H 03H DATA00 DATA01 DATA02 CKS
DATA00: 01H:1 screen
(Matrix diplay function does not work.)
04H:4 screens (2*2 video wall)
09H:9 screens (3*3 video wall)
DATA 01:
00H(fixed)
DATA 02:
01H : Video1
02H : Video2
03H : Video3
04H : COMPNT1
05H : COMPNT2
06H : COMPNT3
07H : PC1DSUB
08H : PC2-BNC
09H : PC3-DVI
*:Turn on the AUTO ID, before this operation
*: This command is used to following system.
1. The system configuration is video wall system (4screens or 9screens).
Then please connect each PDP by wired cable.
In the case of 16 screens or 25 screens video wall system, please refer to No.65.”MULTI MODE Select”.
2. The ID number from a master display is set the continuous number.