Pioneer RS-232 Manuel d'utilisateur Page 12

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 22
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 11
12
RS-232C Adjustment Mode
1.6 GET Commands
What are GET commands?
GET commands are for outputting TXD such as adjustment data from the internal microcomputer of the plasma
display to a PC.
Adjustment data and other information is output as ASCII code.
Note
Command names are given inside brackets < >.
Data output format
Notes
A GET command is invalid when no ID is assigned to the set.
A GET command is invalid when a wildcard (*) is used as par of the ID when sending the command.
1) <GST> (GET STATUS)
Order Data Contents Size Remarks
1 Display data 3 Byte See below
2 Power data 3 Byte See below (The third character is sub input.)
3 Input function data (main) 3 Byte
Input data when GST is received (INPUT1 to 5 is displayed as IN1 to 5.)
4 Input function data (sub) 3 Byte Sub input data when GST is received
Note 3)
(INPUT 1 to 5 is displayed as IN1 to 5.)
5 Screen size data 1 Byte See below
6 2-screen display 1 Byte 0: OFF (1 screen) 1: 2-SCREEN 2: PinP (lower right)
3: PinP (upper right) 4: PinP (upper left) 5: PinP (lower left)
6: PoutP
7 FUNCTIONAL LOCK data 1 Byte 0: LOCK OFF 1: BUTTONS LOCK 2: IR LOCK
3: IR&BUTTONS LOCK 4: MEMORY LOCK
8 Dummy data 3 Byte (3-digit number)
9 Temperature data 2 3 Byte (Internal temperature: Reference value) °C
Note 1)
10 Temperature data 3 3 Byte (External temperature: Reference value) °C
Note 1)
11 Serial 15 Byte
12 Dummy data 3 Byte (3-digit number)
13 Dummy data 3 Byte
14 HOURMETER 5 Byte Displays the time.
15 Check sum 2 Byte
STX (02hex) Data Data ···· Data
ETX (03hex)
Checksum
Display data
First character
Generation data: 4 (fixed)
Second character
Inch data: 4 (43 inch), 5 (50 inch)
Third character
Destination data: M (fixed)
Power data
First character
Power state & signal state
Second character
PN (POWER ON & normal signal input)
PL (POWER ON & no input)
PO (POWER ON & OUT OF RANGE signal input)
SN (Normal standby)
SW (Standby by POWER MANAGMENT)
SS (Standby by SD or PD)
Third character
Sub input signal state during multi-screen display
Note 2)
N (Normal signal input) L (No input)
O (OUT OF RANGE signal input)
Screen size data
First character
0; Dot by Dot or PARTIAL 1; 4 : 3 2; FULL or FULL1080i
3; ZOOM 4;CINEMA 5;WIDE 8;FULL1035i 9; UNDERSCAN
NOTE 1) During Standby and immediately after POWER ON, the proper value is not output. If this occurs, wait a moment
after POWER ON then 'get' the data. The temperature data is output as a reference (the values are not
guaranteed values). Normally, refer to temperature data 3.
NOTE 2) During Standby and during 1-screen display, the unit outputs dummy data (symbol).
NOTE 3) During Standby and during 1-screen display the unit outputs values stored in the product's memory.
Vue de la page 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 21 22

Commentaires sur ces manuels

Pas de commentaire