Operating Instructions– Advanced MCACC PC Display Application Software –AUDIO/VIDEO MULTI-CHANNEL RECEIVER
10 Application Operations (Continued) 4 Select the type of data to be received, then select “OK”. Select “Reverb” to receive the data for the room’s
11 Application Operations (Continued) Graph and parameter displays (names and functions of parts) When measurement data is received, the graphs and p
12 Application Operations (Continued) Group Delay (graph of the speaker’s group delay characteristics) You can switch the display between the speaker
13 Application Operations (Continued) 1 Menu bar and menu icons You can choose the following commands from the application menus. FileOpen Opens a fil
14 Application Operations (Continued) 2 Display item selection tab A graph for the selected item or the MCACC parameter list is displayed. 3 Level [d
15Application Operations (Continued)10 Bar GraphChanges the type of graph display. The display switches between the band graph and bar graph by pressi
16Application Operations (Continued)Saving graphs in data filesYou can save measurement data received from the receiver on your PC. Data received at on
17Application Operations (Continued)Opening data filesYou can open and display two or more data files to compare the data in the files.1 Select “Open” fr
18How to Interpret the GraphsAs indicated in Things you can accomplish with this application (page 3), the reverb characteristics graph can be used as
19How to Interpret the Graphs (Continued)Deciding the time period for Advanced EQ Setup calibrationWith conventional MCACC EQ calibration, the microph
2 About this manual These are the Operating Instructions for an application which displays on your computer screen the listening room reverberation f
20How to Interpret the Graphs (Continued)Pattern 2: Different reverb characteristics for different channelsIf the reverb characteristics differ for th
21How to Interpret the Graphs (Continued)Checking steps to improve your room’s reverb characteristicsThe reverb characteristics of your listening room
22How to Interpret the Graphs (Continued)Case 3: Specific frequency shows unusual reverb characteristicsThere is probably something in the room that af
23How to Interpret the Graphs (Continued)Displaying reverb characteristics after calibrationTo display the graph of your listening area’s reverb chara
24How to Interpret the Graphs (Continued)5 Receive and save the data by selecting “Output PC” from “Data Management”.When you receive and save this in
25How to Interpret the Graphs (Continued)Reading the group delay characteristics graph (Group Delay)Group delay characteristics graphs for before and
26Display of the MCACC parametersIn addition to the reverberation frequency characteristics and group delay characteristics data measured with the Adv
27Updating, Deleting and Repairing the ApplicationUpdating the applicationA new installer is made available on the download site whenever the Advanced
28Updating, Deleting and Repairing the Application (Continued)3 Select “Yes”.The previously installed application is deleted.4 Select “OK”.Installatio
29Updating, Deleting and Repairing the Application (Continued)Deleting the applicationYou can use either of the following methods to uninstall (delete
3 About the Advanced MCACC Application (Continued) Things you can accomplish with this application 1. Advanced EQ Setup, which you can do with the
30Updating, Deleting and Repairing the Application (Continued)4 Select “Remove”.5 Click “Finish”.This completes the deletion of the application.Contin
31Updating, Deleting and Repairing the Application (Continued)Repairing the applicationThe repair function can be used for example if desktop shortcut
32Updating, Deleting and Repairing the Application (Continued)4 Select “Install”.5 Click “Finish”.This completes the repairing of the application.Chan
33TroubleshootingAs you use the Advanced MCACC application, errors can occur for a variety of reasons, such as incompatibilities with other applicatio
34Troubleshooting (Continued)Cause 1: An error message may appear if there are not enough system resources available.If an error message like the one
35Troubleshooting (Continued)Try the following, in the order indicated.1) In the setup screen of the receiver, check that “Start the MCACC application
36Troubleshooting (Continued)Cause:It is not possible to print reverb characteristics graphs displayed in the “ALL” mode.Print after selecting an indi
37Troubleshooting (Continued)Cause 1: The slope of the graph indicates the reverb characteristics. The reverb characteristics of the room itself canno
<ARB7391-A>Published by Pioneer Corporation.Copyright © 2007 Pioneer Corporation.All rights reserved.PIONEER CORPORATION4-1, Meguro 1-Chome, Meg
4 Installing the Application Install this application on your PC by using the downloaded installer.You will find the installer in the folder that you
5 Installing the Application (Continued) 4 Input the Customer Information, then select “Next”. 5 Click “Next”. The application is installed in the fo
6 Installing the Application (Continued) 6 Choose “Install”. A shortcut icon is created on the desktop. 7 Click “Finish”. The installation is compl
7 Operations on the Receiver and Cable Connections Connect the receiver and the computer in order to display on the computer the various data measure
8 Operations on the Receiver and Cable Connections (Continued) 2 Perform the “Auto MCACC (ALL)” operation on the receiver. (See page 8 of the receive
9 Applications Operations This section explains operations that you do in the application, from receiving measurement data to displaying graphs and s
Commentaires sur ces manuels