Pioneer VSX-921 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Systèmes de cinéma à domicile Pioneer VSX-921. Pioneer VSX-921 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 27
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Operating Instructions
– Advanced MCACC PC Display Application Software –
audio/video multi-channel receiver
Vue de la page 0
1 2 3 4 5 6 ... 26 27

Résumé du contenu

Page 1 - Operating Instructions

Operating Instructions– Advanced MCACC PC Display Application Software –audio/video multi-channel receiver

Page 2 - About this manual

10Application Operations (Continued)2 Display item selection tabA graph for the selected item or the MCACC parameter list is displayed.3 Level [dB]The

Page 3

11Application Operations (Continued)11 Bar GraphChanges the type of graph display. The display switches between the band graph and bar graph by pressi

Page 4

12Application Operations (Continued)Saving graphs in data filesThe measurement data transferred from the receiver to the computer is stored in a file

Page 5

13Application Operations (Continued)Opening data filesYou can open and display two or more data files to compare the data in the files.1 Select “Open”

Page 6 - Applications Operations

14How to Interpret the GraphsAs indicated in Things you can accomplish with this application (page 3), the reverb characteristics graph can be used as

Page 7

15How to Interpret the Graphs (Continued)Deciding the time period for Advanced EQ Setup calibrationWith conventional MCACC EQ calibration, the microph

Page 8

16How to Interpret the Graphs (Continued)Pattern 2: Different reverb characteristics for different channelsIf the reverb characteristics differ for th

Page 9

17How to Interpret the Graphs (Continued)Checking steps to improve your room’s reverb characteristicsThe reverb characteristics of your listening room

Page 10 - Continue

18How to Interpret the Graphs (Continued)Case 3: Specific frequency shows unusual reverb characteristicsThere is probably something in the room that a

Page 11

19How to Interpret the Graphs (Continued)About the display of the reverb characteristics graphs before and after calibrationBy comparing the reverbera

Page 12 - Saving graphs in data files

2About this manualThese are the Operating Instructions for an application which displays on your computer screen the listening room reverberation freq

Page 13 - Exiting the application

20How to Interpret the Graphs (Continued)About the types of displays of the graph for the reverb characteristics after EQ calibrationFor “SYMMETRY” or

Page 14 - How to Interpret the Graphs

21How to Interpret the Graphs (Continued)Reading the group delay characteristics graph (Group Delay)Group delay characteristics graphs for before and

Page 15

22Display of the MCACC parametersIn addition to the reverberation frequency characteristics and group delay characteristics data measured with the Adv

Page 16

23Updating the ApplicationYou can check whether or not you need to update the MCACC Application software at “Software Update” on the AVNavigator menu.

Page 17

24TroubleshootingAs you use the Advanced MCACC application, errors can occur for a variety of reasons, such as incompatibilities with other applicatio

Page 18

25Troubleshooting (Continued)Cause 1: An error message may appear if there are not enough system resources available.Restart the computer, and with no

Page 19

26Troubleshooting (Continued)Cause 1: The slope of the graph indicates the reverb characteristics. The reverb characteristics of the room itself canno

Page 20 - (actually measured values)

<ARB7453-A>Published by Pioneer Corporation.Copyright © 2011 Pioneer Corporation.All rights reserved.PIONEER CORPORATION1-1, Shin-ogura, Saiwai-

Page 21

3About the Advanced MCACC Application (Continued)Things you can accomplish with this application 1. Advanced EQ Setup, which you can do with the recei

Page 22

4Transferring measurement data from the receiver to the computerTo display on the computer the various data measured on the receiver, use AVNavigator

Page 23 - Updating the Application

5Transferring measurement data from the receiver to the computer (Continued)• Do not quit AVNavigator or turn off the receiver’s power until data tran

Page 24 - Troubleshooting

6Applications OperationsThis section explains operations from calling out the measurement stored on the computer to displaying graphs and storing data

Page 25

7Application Operations (Continued)Graph and parameter displays (names and functions of parts)When measurement data is received, the graphs and parame

Page 26 - Troubleshooting (Continued)

8Application Operations (Continued)Group Delay (graph of the speaker’s group delay characteristics)You can switch the display between the speaker’s gr

Page 27 - PIONEER CORPORATION

9Application Operations (Continued)1 Menu bar and menu iconsYou can choose the following commands from the application menus.FileOpenCalls out measure

Modèles reliés VSX-1021

Commentaires sur ces manuels

Pas de commentaire